Rise Geo UAE

Calibration and Repairing of Land Survey Equipment at Rise Geo Service Center

Minimize downtime and maximize precision with our expert calibration, repair, and maintenance for your land survey equipment. We service auto levels, total stations, and more, so you can keep your projects on track.

INQUIRE NOW

    Rise Geo Service Center
    Rise Geo Service Center

    About Services

    We Offer a Full Range of Services!

    Core Services

    Total stations need to be checked and calibrated chronologically every 6 months for the finest performance with precision, particularly due to the atmospheric conditions in the region. Total stations for calibration will undergo the following procedures for a Complete Overhaul under regularly controlled temperatures.

    • Tribrach Service – Cleaning and confirming smooth rotation of Levelling Screws
    • Hz Encoder System – Set the Hz Constants in Service mode for correct Hz readings in User mode
    • V Encoder System – Set the Hz Constants in Service mode for correct Hz readings in User mode
    • Focus – Dismantling, cleaning, Re-greasing with special grease, assembling of focusing tube, and cleaning all lenses.
    • External instrumental cleaning.
    • Collimation check and adjustment on Collimator
    • Horizontality check and adjustment on Collimator
    • Alignment of EDM Laser beam to the Reticle of the instrument.
    • Final Calibration on 4-target Collimator system
    • Base Line checks to verify EDM constants.
    • Cleaning of Carrying Cases.
    • Issue of Calibration Certificate for 6 months, wherein a Calibration
    • Warranty is also provided during this period.

    All auto-level brands need to be checked and calibrated chronologically every 6 months to give accurate readings during the survey. Auto-levels for calibration will undergo the following procedures for a Complete Overhaul.

    • Level Base service – Dismantling, Cleaning, Re-greasing with special grease, and assembling
    • Worm Drive – Dismantling, cleaning, Re-greasing with special grease, assembling.
    • Focus Drive – Dismantling, cleaning, Re-greasing with special grease, assembling of Focusing tube, Pinion complete, and cleaning all lenses.
    • Compensator Check – Compensator check and adjustment if needed.
    • External instrumental cleaning.
    • Final Calibration on Collimator.
    • Cleaning of Carrying Cases.
    • Issue of Calibration Certificate for 6 months, wherein a Calibration warranty is also provided during this period.

    Though GPS survey has not entirely replaced surveying field instruments, it is widely used in the region. Hence it is important to conduct periodic checks to confirm the satellite connectivity and upgrade the firmware version to stay updated.

    • Satellite corrections receive checks
    • RTK/VRS connectivity checks
    • Base-Rover connectivity checks
    • Base station Radio Rx/Tx Channel/Frequency checks
    • Radio Link Rate Check
    • Radio Transmit Power and Signal Strength check
    • Replacement of boards or connectors in case of any damages
    • Data Controller Firmware and Software upgrades
    • GPS Firmware upgrades
    • External Cleaning
    • Issue of Test Certificates for 6 months/1 Year

    Faulty or Damaged Cables and Connectors can extremely hinder the performance of GPS/GNSS receivers. Therefore, these must be in good condition with no damages or cracks in them. All cables and connectors are checked and damages repaired in case of any ruptures or breakages. Further, they are rechecked to confirm proper performance and connectivity.

    Repair and Calibrate Your Equipment Now with Rise Geo

    Reach out today to benefit from our advanced equipment and skilled professionals for accurate land surveying solutions for your needs.

    Scroll to Top